Starting generation of Calibration File FS version = 0009.0009.0002 time_zero = 1699200 Found #514 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #50 errors of type = ERROR ch -4 Device vf timed-out on response from MATCN Found #19 errors of type = ERROR ch -303 vf bandwidth does not check with requested value Found #19 errors of type = ERROR ch -302 vf frequency does not check with requested value Found #19 errors of type = ERROR ch -304 vf TPI selection does not check with requested setting Found #19 errors of type = ERROR ch -309 vf alarm is on Found #18 errors of type = ERROR ch -305 vf USB attenuator does not check with requested setting Found #18 errors of type = ERROR ch -306 vf LSB attenuator does not check with requested setting Found #15 errors of type = ERROR ma -4 Device vf timed-out on response. Found #10 errors of type = ERROR ch -307 vf unlock indicator is on Found #7 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #6 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #3 errors of type = ERROR ch -350 The Receiver 20K stage is hotter than 40K. Found #3 errors of type = ERROR ch -309 vd alarm is on Found #2 errors of type = ERROR m5 -900 Check formatter serial number even Found #2 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or was less than zero. Found #2 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found #1 errors of type = ERROR ch -303 vc bandwidth does not check with requested value Found #1 errors of type = ERROR ch -302 v4 frequency does not check with requested value Found #1 errors of type = ERROR ch -306 vd LSB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -304 v9 TPI selection does not check with requested setting Found #1 errors of type = ERROR sp -3 More than 12 characters in function or procedure name. Found #1 errors of type = ERROR ch -302 vb frequency does not check with requested value Found #1 errors of type = ERROR ch -304 v5 TPI selection does not check with requested setting Found #1 errors of type = ERROR ch -306 v2 LSB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -307 v6 unlock indicator is on Found #1 errors of type = ERROR ch -309 v4 alarm is on Found #1 errors of type = ERROR ch -306 vb LSB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -370 Total power integrator overflow on IF3 Found #1 errors of type = ERROR ch -303 v9 bandwidth does not check with requested value Found #1 errors of type = ERROR ch -309 v1 alarm is on Found #1 errors of type = ERROR ch -302 va frequency does not check with requested value Found #1 errors of type = ERROR ch -305 v4 USB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -304 v4 TPI selection does not check with requested setting Found #1 errors of type = ERROR ch -306 v7 LSB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -309 v3 alarm is on Found #1 errors of type = ERROR ch -307 vb unlock indicator is on Found #1 errors of type = ERROR ch -303 v3 bandwidth does not check with requested value Found #1 errors of type = ERROR ch -309 vb alarm is on Found #1 errors of type = ERROR ch -302 v3 frequency does not check with requested value Found #1 errors of type = ERROR ch -302 v9 frequency does not check with requested value Found #1 errors of type = ERROR ch -305 ve USB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -303 v2 bandwidth does not check with requested value Found #1 errors of type = ERROR ch -306 va LSB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -303 ve bandwidth does not check with requested value Found #1 errors of type = ERROR ch -302 ve frequency does not check with requested value Found #1 errors of type = ERROR ch -305 v9 USB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -305 v1 USB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -305 vb USB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -302 v5 frequency does not check with requested value Found #1 errors of type = ERROR ch -363 IF3 mixer state does not check with request. Found #1 errors of type = ERROR ch -362 IF3 attenuator does not check with requested value. Found #1 errors of type = ERROR ch -306 v8 LSB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -302 vc frequency does not check with requested value Found #1 errors of type = ERROR ch -304 v3 TPI selection does not check with requested setting Found #1 errors of type = ERROR ch -303 v1 bandwidth does not check with requested value Found #1 errors of type = ERROR ch -309 v7 alarm is on Found #1 errors of type = ERROR ch -306 ve LSB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -302 v8 frequency does not check with requested value Found #1 errors of type = ERROR ch -305 va USB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -309 vc alarm is on Found #1 errors of type = ERROR ch -309 v5 alarm is on Found #1 errors of type = ERROR ch -304 vc TPI selection does not check with requested setting Found #1 errors of type = ERROR ch -304 v7 TPI selection does not check with requested setting Found #1 errors of type = ERROR ch -303 v7 bandwidth does not check with requested value Found #1 errors of type = ERROR ch -307 vc unlock indicator is on Found #1 errors of type = ERROR ch -302 v1 frequency does not check with requested value Found #1 errors of type = ERROR ch -306 v9 LSB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -309 v6 alarm is on Found #1 errors of type = ERROR ch -303 v6 bandwidth does not check with requested value Found #1 errors of type = ERROR ch -303 va bandwidth does not check with requested value Found #1 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #1 errors of type = ERROR ch -306 v5 LSB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -306 v4 LSB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -307 v8 unlock indicator is on Found #1 errors of type = ERROR ch -304 v2 TPI selection does not check with requested setting Found #1 errors of type = ERROR ch -306 v6 LSB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -307 v3 unlock indicator is on Found #1 errors of type = ERROR ch -304 ve TPI selection does not check with requested setting Found #1 errors of type = ERROR ch -309 v2 alarm is on Found #1 errors of type = ERROR ch -304 vd TPI selection does not check with requested setting Found #1 errors of type = ERROR ch -303 vd bandwidth does not check with requested value Found #1 errors of type = ERROR ch -307 vd unlock indicator is on Found #1 errors of type = ERROR ch -308 vc total power integrator overflow Found #1 errors of type = ERROR ch -304 v6 TPI selection does not check with requested setting Found #1 errors of type = ERROR ch -305 v3 USB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -303 v5 bandwidth does not check with requested value Found #1 errors of type = ERROR ch -304 vb TPI selection does not check with requested setting Found #1 errors of type = ERROR ch -309 v8 alarm is on Found #1 errors of type = ERROR ch -309 va alarm is on Found #1 errors of type = ERROR ch -307 v5 unlock indicator is on Found #1 errors of type = ERROR ch -305 v8 USB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -303 v4 bandwidth does not check with requested value Found #1 errors of type = ERROR ch -305 v6 USB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -302 vd frequency does not check with requested value Found #1 errors of type = ERROR ch -306 vc LSB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -304 va TPI selection does not check with requested setting Found #1 errors of type = ERROR ch -307 v7 unlock indicator is on Found #1 errors of type = ERROR ch -302 v2 frequency does not check with requested value Found #1 errors of type = ERROR ch -305 vc USB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -306 v1 LSB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -305 v2 USB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -305 v7 USB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -305 vd USB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -303 vb bandwidth does not check with requested value Found #1 errors of type = ERROR ch -303 v8 bandwidth does not check with requested value Found #1 errors of type = ERROR ch -302 v6 frequency does not check with requested value Found #1 errors of type = ERROR ch -306 v3 LSB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -305 v5 USB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -309 ve alarm is on Found #1 errors of type = ERROR ch -302 v7 frequency does not check with requested value Found these BBCs: vc06 vc11 NBBC: 2 Found these RX parameters: front rear lo RX1 min= 100000 max= 2010.019.16:52:16.29 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 2 Tsys channels: 06 11 Tsys values are: 1 2 3 etc NTSYS: 2 in match_chan ft1= r1414ho.log.tsy1.ntup nt1= 20 st1= 6u tt= 1 set scale tsys1 [2] min max 61.7 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 45.2 ymax 305 in match_chan ft1= r1414ho.log.tsy1.ntup nt1= 14 st1= bu tt= 1 set scale tsys1 [2] min max 61.7 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 34 ymax 305