Starting generation of Calibration File FS version = 0009.0010.0004 time_zero = 2214000 Found #146 errors of type = ERROR st -903 The Receiver 20K stage is hotter than 30K. Found #112 errors of type = ERROR st -7 Antenna off-source! Found #50 errors of type = ERROR ma -4 Device v3 timed-out on response. Found #26 errors of type = ERROR ch -370 Total power integrator overflow on IF3 Found #11 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #11 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #6 errors of type = ERROR ma -4 Device v1 timed-out on response. Found #4 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. Found #4 errors of type = ERROR ch -308 v5 total power integrator overflow Found #4 errors of type = ERROR ch -4 Device vf timed-out on response from MATCN Found #4 errors of type = ERROR ma -4 Device vf timed-out on response. Found #2 errors of type = ERROR m5 -900 Check formatter serial number even Found #2 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #2 errors of type = ERROR ch -4 Device v5 timed-out on response from MATCN Found #2 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found #1 errors of type = ERROR ch -306 v5 LSB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -302 vf frequency does not check with requested value Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 6u. Found #1 errors of type = ERROR ch -304 vf TPI selection does not check with requested setting Found #1 errors of type = ERROR ch -302 v5 frequency does not check with requested value Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 4u. Found #1 errors of type = ERROR ch -307 vf unlock indicator is on Found #1 errors of type = ERROR ch -304 v5 TPI selection does not check with requested setting Found #1 errors of type = ERROR ch -303 v5 bandwidth does not check with requested value Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 1u. Found #1 errors of type = ERROR ch -305 v5 USB attenuator does not check with requested setting Found #1 errors of type = ERROR ch -309 vf alarm is on Found #1 errors of type = ERROR ch -305 vf USB attenuator does not check with requested setting Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 5u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 3u. Found #1 errors of type = ERROR 4f -509 Possible bit slip Altera clock and sync misalign errors. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 5u. Found #1 errors of type = ERROR ch -307 v5 unlock indicator is on Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 8u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector i3. Found #1 errors of type = ERROR ch -303 vf bandwidth does not check with requested value Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 7u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector i3. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector i1. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 8u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 6u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 7u. Found #1 errors of type = ERROR ch -309 v5 alarm is on Found #1 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 4u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 3u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 2u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector i1. Found #1 errors of type = ERROR ch -306 vf LSB attenuator does not check with requested setting Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 1u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 2u. Found these BBCs: NBBC: 0 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 0 Tsys channels: Tsys values are: 1 2 3 etc NTSYS: 0