Starting generation of Calibration File FS version = 0009.0011.0008 time_zero = 784800 Found #6029 errors of type = ERROR ch -350 The Receiver 20K stage is hotter than 40K. Found #1850 errors of type = ERROR ch -349 The Receiver 70K stage is hotter than 85K. Found #438 errors of type = ERROR qk -202 TPIs are ALL EVENU ODDU EVENL ODDL IFA-D 1u 1l ...14u 14l FORMBBC FORMIF. Found #242 errors of type = ERROR sp -13 This command not supported for your equipment check equip.ctl. Found #101 errors of type = ERROR qk -211 Tsys value for device eu overflowed or was less than zero. Found #98 errors of type = ERROR di -201 IF input must be 1-4. Found #75 errors of type = ERROR qk -211 Tsys value for device du overflowed or was less than zero. Found #69 errors of type = ERROR qk -211 Tsys value for device cu overflowed or was less than zero. Found #58 errors of type = ERROR qk -211 Tsys value for device ic overflowed or was less than zero. Found #51 errors of type = ERROR qk -211 Tsys value for device id overflowed or was less than zero. Found #43 errors of type = ERROR qk -211 Tsys value for device 9u overflowed or was less than zero. Found #32 errors of type = ERROR qk -211 Tsys value for device au overflowed or was less than zero. Found #31 errors of type = ERROR qk -211 Tsys value for device bu overflowed or was less than zero. Found #15 errors of type = ERROR qk -211 Tsys value for device ia overflowed or was less than zero. Found #15 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #14 errors of type = ERROR qk -211 Tsys value for device ib overflowed or was less than zero. Found #13 errors of type = ERROR qk -211 Tsys value for device 8l overflowed or was less than zero. Found #12 errors of type = ERROR qk -211 Tsys value for device 1u overflowed or was less than zero. Found #12 errors of type = ERROR qk -211 Tsys value for device 6u overflowed or was less than zero. Found #11 errors of type = ERROR qk -211 Tsys value for device 1l overflowed or was less than zero. Found #10 errors of type = ERROR qk -211 Tsys value for device 7u overflowed or was less than zero. Found #10 errors of type = ERROR qk -211 Tsys value for device 4u overflowed or was less than zero. Found #10 errors of type = ERROR qk -211 Tsys value for device 8u overflowed or was less than zero. Found #9 errors of type = ERROR sc -13 setcl: formatter to FS time difference 0.5 seconds or greater Found #9 errors of type = ERROR qk -211 Tsys value for device 2u overflowed or was less than zero. Found #9 errors of type = ERROR qk -211 Tsys value for device 5u overflowed or was less than zero. Found #7 errors of type = ERROR qk -211 Tsys value for device 3u overflowed or was less than zero. Found #5 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #4 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #2 errors of type = ERROR m5 -900 : Data transfer in progress Found #2 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found #1 errors of type = ERROR bo -105 Error opening schedule file FMP FFF Found #1 errors of type = ERROR ch -308 vc total power integrator overflow Found these BBCs: vc06 vc11 NBBC: 2 Found these RX parameters: 00(front) 01(rear) 02(lo) RX1 min= 23.01 max= 34.73 RX2 min= 34.24 max= 45.48 RX3 min= 45.97 max= 54.88 Plotting 2 Tsys channels: 06 11 Tsys values are: -1 1 2 etc NTSYS: 2 in match_chan ft1= crf104ho.log.tsy1.ntup nt1= 14 st1= 6u tt= 1 set scale tsys1 [2] min max -5 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin -5 ymax 305 in match_chan ft1= crf104ho.log.tsy1.ntup nt1= 21 st1= bu tt= 1 set scale tsys1 [2] min max -5 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin -5 ymax 305