IVS Analysis Report for I18361 ($18DEC27XU) This report is the official IVS analysis report that corresponds to the database maintained by the IVS Data Centers for this session. (Analyzed by Karen Baver, Goddard Space Flight Center VLBI Analysis Center. Spoolfile source: interactive solve/nuSolve analysis.) Problems: The SVETLOE baselines had high residuals. Number of observations rejected during correlation: 10 WETTZ13N:WETTZELL, 1929+226, 18:35:53 --- not in data base: probable G- or H- code in one or both bands WETTZ13N:WETTZELL, 3C371 , 18:43:39 --- not in data base: probable G- or H- code in one or both bands WETTZ13N:WETTZELL, 2013+163, 18:50:37 --- not in data base: probable G- or H- code in one or both bands SVETLOE :WETTZELL, 1015+359, 18:59:31 --- not in data base: probable G- or H- code in one or both bands KOKEE :SVETLOE , 1803+784, 19:03:25 --- not in data base: probable G- or H- code in one or both bands SVETLOE :WETTZ13N, 1803+784, 19:03:25 --- not in data base: probable G- or H- code in one or both bands SVETLOE :WETTZELL, 1803+784, 19:03:25 --- not in data base: probable G- or H- code in one or both bands KOKEE :SVETLOE , 1053+815, 19:18:54 --- not in data base: probable G- or H- code in one or both bands SVETLOE :WETTZ13N, 1053+815, 19:18:54 --- not in data base: probable G- or H- code in one or both bands SVETLOE :WETTZELL, 1053+815, 19:18:54 --- not in data base: probable G- or H- code in one or both bands Number of observations not usable by the software: 7 observation 10, KOKEE :WETTZ13N, 1929+226, 18:35:53, quality code X-band: 0 S-band: 9 observation 11, KOKEE :WETTZELL, 1929+226, 18:35:53, quality code X-band: 0 S-band: 9 observation 31, KOKEE :WETTZ13N, 2013+163, 18:50:37, quality code X-band: 9 S-band: 0 observation 32, KOKEE :WETTZELL, 2013+163, 18:50:37, quality code X-band: 9 S-band: 0 observation 55, KOKEE :WETTZ13N, 1636+473, 19:06:07, quality code X-band: 9 S-band: 0 observation 56, KOKEE :WETTZELL, 1636+473, 19:06:07, quality code X-band: 9 S-band: 0 observation 86, KOKEE :WETTZ13N, 1636+473, 19:27:17, quality code X-band: 9 S-band: 0 Number of observations rejected during analysis: 42 The KOKEE:SVETLOE, SVETLOE:WETTZ13N, and SVETLOE:WETTZELL baselines were deselected due to high residuals. The WETTZ13N:WETTZELL baseline was deselected, as usual for the GSFC VLBI AC's processing of INT01 sessions. Other comments: None. Parameterization: 10 parameters: UT1 offset atmosphere offset for: KOKEE WETTZ13N WETTZELL clock offset, first order term, and second order term for: WETTZ13N WETTZELL Clock breaks: None Session Statistics Observations: 90 scheduled 80 correlated (included in the database) 73 recoverable (usable in Solve/nuSolve) 31 used Session fit: 48.332 ps UT1 formal error: 11.32 microsec Source Performance Number of Observations Scheduled Correlated* Used 0716+714 6 6 2 0920+390 6 6 2 0955+476 12 12 4 1015+359 12 11 4 1053+815 6 3 2 1300+580 6 6 4 1418+546 6 6 2 1636+473 9 9 1 1732+389 3 3 2 1803+784 6 3 2 3C371 6 5 2 1846+322 3 3 2 1929+226 3 2 0 2013+163 3 2 0 2229+695 3 3 2 ------------ --------- ---------- ------ Source Total 90 80 31 * Correlated means included in the database. Please note that the number of recoverable (usable) observations cannot be broken down by source for Intensive solutions.