USNO Analysis Report for Q18043 ($18FEB12XK) This report is a contributed analysis report that does not correspond to the database maintained by the IVS Data Centers for this session. (Analyzed by Christopher Dieck, US Naval Observatory. Spoolfile source: interactive nuSolve analysis.) Problems: The correlator reports that NYALES20 reports that they "observed with warm receiver due to power outage in the receiver box. Only a hand-full of 'useable' scans in X-band with very low SNR; S-band okay" and that SESHAN25 had "RFI in S-band, particularly strong in channel SR5U." Number of observations rejected during correlation: 0 Number of observations not usable by the software: 50 49 scans were not usuable due to the issues at NYALES20 identified in the station report. The other scan was: observation 18, ISHIOKA :WETTZELL, 0642+449, 07:02:39, quality code X-band: 0 S-band: 9 Number of observations rejected during analysis: 21 The 21 scans of the WETTZ13N:WETTZELL baseline were deselected as is the practice of this analysis center. Other comments: None. Parameterization: 14 parameters: UT1 offset atmosphere offset for: ISHIOKA NYALES20 SESHAN25 WETTZ13N WETTZELL clock offset (0), first order term (1), and/or second order term (2) for: ISHIOKA (0,1) NYALES20 (0,1) SESHAN25 (0,1) WETTZ13N (0,1) Clock breaks: None Session Statistics Observations: 210 scheduled 210 correlated (included in the database) 160 recoverable (usable in Solve/nuSolve) 139 used Session fit: 41.110 ps UT1 formal error: 5.84 microsec Source Performance Number of Observations Scheduled Correlated* Used 0059+581 10 10 9 0133+476 10 10 9 2113+293 10 10 5 2209+236 10 10 6 2318+049 20 20 10 1800+440 10 10 7 2000+472 10 10 7 2215+150 10 10 5 0529+483 20 20 16 0716+714 10 10 5 2141+175 10 10 7 0016+731 10 10 8 0017+200 20 20 12 0202+319 20 20 15 0642+449 10 10 4 1039+811 10 10 6 1849+670 10 10 8 ------------ --------- ---------- ------ Source Total 210 210 139 * Correlated means included in the database. Please note that the number of recoverable (usable) observations cannot be broken down by source for Intensive solutions.