Starting generation of Calibration File FS version = 0009.0011.0019 time_zero = 1353600 Found #267 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #230 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #81 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #18 errors of type = ERROR qk -211 Tsys value for device ve overflowed or was less than zero. Found #15 errors of type = ERROR ch -4 Device v1 timed-out on response from MATCN Found #14 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #13 errors of type = ERROR ch -4 Device v6 timed-out on response from MATCN Found #13 errors of type = ERROR ch -4 Device v2 timed-out on response from MATCN Found #13 errors of type = ERROR ch -4 Device v3 timed-out on response from MATCN Found #13 errors of type = ERROR ch -4 Device v8 timed-out on response from MATCN Found #13 errors of type = ERROR ch -4 Device v4 timed-out on response from MATCN Found #13 errors of type = ERROR ch -4 Device v7 timed-out on response from MATCN Found #13 errors of type = ERROR ch -4 Device v5 timed-out on response from MATCN Found #13 errors of type = ERROR ch -4 Device v9 timed-out on response from MATCN Found #12 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #12 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. Found #6 errors of type = ERROR ma -4 Device if timed-out on response. Found #6 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or was less than zero. Found #6 errors of type = ERROR ma -4 Device i3 timed-out on response. Found #6 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #4 errors of type = ERROR ma -4 Device v2 timed-out on response. Found #4 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. Found #4 errors of type = ERROR ma -4 Device vc timed-out on response. Found #4 errors of type = ERROR ma -4 Device v8 timed-out on response. Found #4 errors of type = ERROR ma -4 Device v5 timed-out on response. Found #4 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or was less than zero. Found #4 errors of type = ERROR ma -4 Device v4 timed-out on response. Found #4 errors of type = ERROR ma -4 Device va timed-out on response. Found #4 errors of type = ERROR ma -4 Device v3 timed-out on response. Found #4 errors of type = ERROR ma -4 Device v6 timed-out on response. Found #4 errors of type = ERROR ma -4 Device v9 timed-out on response. Found #4 errors of type = ERROR ma -4 Device ve timed-out on response. Found #4 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or was less than zero. Found #4 errors of type = ERROR ma -4 Device vb timed-out on response. Found #4 errors of type = ERROR ma -4 Device vd timed-out on response. Found #4 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #4 errors of type = ERROR ma -4 Device v1 timed-out on response. Found #4 errors of type = ERROR ma -4 Device v7 timed-out on response. Found #4 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or was less than zero. Found #2 errors of type = ERROR ma -4 Device fm timed-out on response. Found #2 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #1 errors of type = ERROR m5 -900 : Check formatter serial number even Found #1 errors of type = ERROR ch -308 v9 total power integrator overflow Found #1 errors of type = ERROR 5h -302 background Mark 5 error(s) detected - see below Found #1 errors of type = ERROR ch -308 vc total power integrator overflow Found #1 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these RX parameters: 02(LO) 03(DCAL) 05(INLET) RX1 min= 45.59 max= 55.11 RX2 min= 37.97 max= 45.59 RX3 min= 30.35 max= 42.73 Plotting 3 Tsys channels: 01 05 09 Tsys values are: 1 2 3 etc NTSYS: 3 in match_chan ft1= r1825ft.log.tsy1.ntup nt1= 7 st1= 1d tt= 1 set scale tsys1 [2] min max 102.6 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 135.6 ymax 305 in match_chan ft1= r1825ft.log.tsy1.ntup nt1= 19 st1= 5u tt= 1 set scale tsys1 [2] min max 102.6 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 140.8 ymax 305 in match_chan ft1= r1825ft.log.tsy1.ntup nt1= 12 st1= 9u tt= 1 set scale tsys1 [2] min max 102.6 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 106.5 ymax 305