Starting generation of Calibration File FS version = 0009.0011.0019 time_zero = 3772800 Found #3 errors of type = ERROR fl -1 Previous source in this schedule not reached before new source was commanded Found #2 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #2 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #1 errors of type = ERROR qk -211 Tsys value for device 1u overflowed or was less than zero. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 6u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 4u. Found #1 errors of type = ERROR qk -211 Tsys value for device ic overflowed or was less than zero. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 1u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 8l. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 5u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 8l. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 3u. Found #1 errors of type = ERROR qz -205 Integration period must be between 1 and 32. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 5u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector ia. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 8u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector ia. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 7u. Found #1 errors of type = ERROR qk -211 Tsys value for device 1l overflowed or was less than zero. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 1l. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 8u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 6u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 7u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector ib. Found #1 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 4u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 3u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 2u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector ib. Found #1 errors of type = ERROR qk -211 Tsys value for device au overflowed or was less than zero. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 1l. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 1u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 2u. Found these BBCs: NBBC: 0 Found these SK parameters: get get get RX1 min= 100000 max= 2018.043.17:00:03.16 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 0 Tsys channels: Tsys values are: -1 1 2 etc NTSYS: 0