Starting generation of Calibration File FS version = 0009.0011.0019 time_zero = 406800 Found #343 errors of type = ERROR st -4 Interface not set to remote. Found #247 errors of type = ERROR fl -1 Previous source in this schedule not reached before new source was commanded Found #144 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #144 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #107 errors of type = ERROR st -7 Antenna off-source! Found #8 errors of type = ERROR st -6 Antenna control restored. Found #6 errors of type = ERROR qk -211 Tsys value for device ic overflowed or was less than zero. Found #5 errors of type = ERROR 5k 302 There have not been two scan_name ... commands since the schedule started use scan_check force to force check Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 6u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 4u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 1u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 8l. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 5u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 8l. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 3u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 5u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector ia. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 8u. Found #1 errors of type = ERROR m5 -900 : not doing anything Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector ia. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 7u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 1l. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 8u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 6u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 7u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector ib. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 4u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 3u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 2u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector ib. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 1l. Found #1 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 1u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 2u. Found these BBCs: NBBC: 0 Found these SK parameters: get get get RX1 min= 100000 max= 2018.004.18:32:38.17 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 0 Tsys channels: Tsys values are: -1 1 2 etc NTSYS: 0