Starting generation of Calibration File FS version = 0009.0012.0011 time_zero = 5245200 Found #16 errors of type = ERROR st -5 Antenna communication error see above errors. Found #15 errors of type = ERROR st -999 Reply time-out Found #15 errors of type = ERROR st 26 ACU-FS Time difference now nominal. Found #5 errors of type = ERROR st -998 read ReadGroup Found #3 errors of type = ERROR st 6 ACU-FS time difference -252 ms exceeds 250 ms. Found #3 errors of type = ERROR st -76 Azimuth Slave Brake Alarm on. Found #3 errors of type = ERROR st -72 Elevation (motor) Brake Alarm on. Found #3 errors of type = ERROR st -66 Azimuth Master Brake Alarm on. Found #3 errors of type = ERROR st -998 write regs Found #3 errors of type = ERROR st -998 write ReadGroup Found #3 errors of type = ERROR st -53 Antenna control timed-out. Found #3 errors of type = ERROR st -77 Elevation Slave Brake Alarm on. Found #3 errors of type = ERROR st -47 Antenna Control Timeout should be enabled but is disabled. Found #3 errors of type = ERROR st -50 Antenna NOT fully moveable see above errors. Found #2 errors of type = ERROR st 6 ACU-FS time difference -264 ms exceeds 250 ms. Found #2 errors of type = ERROR st -998 write timeout reset Found #2 errors of type = ERROR 2b -303 IF 1 RMS too low rdbca Found #2 errors of type = ERROR st -998 reading epoch Found #2 errors of type = ERROR m6 -104 mk6ca: time-out connection closed will reopen on next attempt Found #2 errors of type = ERROR st -24 Antenna not ready verify condition start with antenna operate Found #2 errors of type = ERROR st 6 ACU-FS time difference -256 ms exceeds 250 ms. Found #1 errors of type = ERROR st 6 ACU-FS time difference -304 ms exceeds 250 ms. Found #1 errors of type = ERROR st 6 ACU-FS time difference -258 ms exceeds 250 ms. Found #1 errors of type = ERROR st 6 ACU-FS time difference -275 ms exceeds 250 ms. Found #1 errors of type = ERROR 2b -304 IF 0 RMS too high rdbca Found #1 errors of type = ERROR st 6 ACU-FS time difference -260 ms exceeds 250 ms. Found #1 errors of type = ERROR st 6 ACU-FS time difference -283 ms exceeds 250 ms. Found #1 errors of type = ERROR st 6 ACU-FS time difference -255 ms exceeds 250 ms. Found #1 errors of type = ERROR st 6 ACU-FS time difference -273 ms exceeds 250 ms. Found #1 errors of type = ERROR st -998 reading AzimuthMasterStatus Found #1 errors of type = ERROR st -93 Wait for power-off and drives to trip timed-out. Found #1 errors of type = ERROR st 6 ACU-FS time difference -319 ms exceeds 250 ms. Found #1 errors of type = ERROR st -999 Illegal Data Address exception response Found #1 errors of type = ERROR st 6 ACU-FS time difference -328 ms exceeds 250 ms. Found #1 errors of type = ERROR st 6 ACU-FS time difference -268 ms exceeds 250 ms. Found #1 errors of type = ERROR st 6 ACU-FS time difference -270 ms exceeds 250 ms. Found #1 errors of type = ERROR st -14 Switch to operate and brakes releasing timed-out. Found these BBCs: NBBC: 0 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 0 Tsys channels: NTSYS: 0