==================================== crf114 ==================================== Ma : Stopped at 11:43 for technical reason. Zc : Partcicpated in RI2930 (19:51-21:00). No problems found for : Hh, Mc, Ys ================================ crf114hh READY ================================ 2019-11-28 13:47:54 crf114, HartRAO, Ready-message Session crf114 ready message for HartRAO. ----------------------------------------- Comments: HartRAO is ready to start CRF114 All systems nominal First source: 2348-010 at 14:00:00 UT FMOUT-GPS: 1.5227 microseconds Wx: Temperature (C): 30.5 Pressure (mBar): 863.3 Humidity (%): 36.31 Sky Conditions: 10-20% cloud and hazy Cable difference is: longer cable makes the reading smaller by 554.3 microseconds and is nominal Pointing values: na Tsys (x1/s/x2): 51.8/59.0/56.4 ================================ crf114hh START ================================ 2019-11-28 14:00:00 crf114, HartRAO, Autostart-message Session crf114 auto-start message for HartRAO. ---------------------------------------------- Started recording with source: 2348-010 at 332.14:00:00 UT ================================ crf114hh STOP ================================= 2019-11-29 14:02:13 crf114, HartRAO, Stop-message Session crf114 stop message for HartRAO. ---------------------------------------- Comments: HartRAO has completed CRF114 Weather conditions:10-20% cloud and hazy at start,partly cloudy midway and lite overcast at end. Data will be e-shipped to SHAO Disk Inventory: A 0, B 2, C 0, D 1, E 1, F 0, G 0, H 0, (other larger) 7 Observation finished at: 14:00:00 UT ================================ crf114ma READY ================================ 2019-11-28 09:17:49 CRF114, MATERA, Ready-message Session CRF114 ready message for MATERA. ---------------------------------------- First source: 2348-010 at 14:00:00 UT GPS-FMOUT: 9.525 microseconds Wx: Temperature (C): 13.2 Pressure (mBar): 954.2 Humidity (%): 84 Sky Conditions: Cloudy sky Cable difference is: longer cable makes the reading smaller by 253.1 microseconds and is nominal Pointing values: SEFD X/S Source Az/El Offset1 Offset2 1495/1344 Cygnusa 61/31 -0.0004 0.0075 Tsys (x1/s/x2): 64/245/0 ================================ crf114ma START ================================ 2019-11-28 14:06:52 crf114, MATERA, Start-message Session crf114 start message for MATERA. ---------------------------------------- Started recording with source: 2227-088 at: 14:06:36 UT ================================ crf114ma STOP ================================= 2019-11-29 12:27:55 CRF114, MATERA, Stop-message Session CRF114 stop message for MATERA. --------------------------------------- Comments: Session stopped at 11:34 for technical reason Problem scans: Source Scan start Explanation of problem 0 0 0 Disk Inventory: A 0, B 0, C 0, D 0, E 0, F 0, G 0, H 0, (other larger) 7 Observation finished at: 11:34 UT ================================ crf114mc READY ================================ 2019-11-28 12:44:59 crf114, Medicina, Ready-message Session crf114 ready message for Medicina. ------------------------------------------ First source: 2348-010 at 14:00 UT GPS-FMOUT: 10.9 microseconds Wx: Temperature (C): 9.4 Pressure (mBar): 1001.9 Humidity (%): 97.6 Sky Conditions: cloudy Cable difference is: na Pointing values: SEFD X/S Source Az/El Offset1 Offset2 379/531 3c380 67/69 0.004 -0.004 327/577 3c295 302/53 0.004 -0.001 Tsys (x1/s/x2): 35/66/30 ================================ crf114mc READY ================================ 2019-11-28 12:48:26 crf114, Medicina, Ready-message Session crf114 ready message for Medicina. ------------------------------------------ First source: 2348-010 at 14:00 UT GPS-FMOUT: 10.9 microseconds Wx: Temperature (C): 9.4 Pressure (mBar): 1001.9 Humidity (%): 97.6 Sky Conditions: cloudy Cable difference is: na Pointing values: SEFD X/S Source Az/El Offset1 Offset2 379/531 3c380 67/69 0.004 -0.004 327/577 3c295 302/53 0.004 -0.001 Tsys (x1/s/x2): 35/66/30 ================================ crf114mc START ================================ 2019-11-28 14:00:02 crf114, Medicina, Autostart-message Session crf114 auto-start message for Medicina. ----------------------------------------------- Started recording with source: 2348-010 at 332.14:00:02 UT ================================ crf114mc STOP ================================= 2019-11-29 14:01:26 crf114, Medicina, Stop-message Session crf114 stop message for Medicina. ----------------------------------------- Comments: ok, all done. Observation finished at: 14:00 UT ================================ crf114ys READY ================================ 2019-11-28 14:10:54 crf114, Yebes40m, Ready-message Session crf114 ready message for Yebes40m. ------------------------------------------ Comments: Overcast First source: 2348-010 at 14:00:00 UT GPS-FMOUT: +8.5208 microseconds Wx: Temperature (C): 8.20 Pressure (mBar): 911.2 Humidity (%): 95 Sky Conditions: Overcast Cable difference is: longer cable makes the reading larger by 608.5 microseconds and is nominal Pointing values: SEFD X/S Source Az/El Offset1 Offset2 180.6/1353 3c454 87.4/26.8 0 0 Tsys (x1/s/x2): 61.7/374.5/55.4 ================================ crf114ys START ================================ 2019-11-28 14:00:05 crf114, Yebes40m, Start-message Session crf114 start message for Yebes40m. ------------------------------------------ Started recording with source: 2348-010 at: 14:00:00 UT ================================ crf114ys STOP ================================= 2019-11-29 14:24:53 crf114ys, Yebes40m, Stop-message Session crf114ys stop message for Yebes40m. ------------------------------------------- Problem scans: Source Scan start Explanation of problem 0 0 0 Disk Inventory: A 0, B 0, C 1, D 2, E 0, F 0, G 3, H 0, (other larger) 3 Observation finished at: 14:00:00 UT ================================ crf114zc READY ================================ 2019-11-28 12:27:20 crf114 Zelenchukskaya Ready message Session crf114 ready message for Zelenchukskaya. First source: 2348-010 at 14:00:00 UT. GPS-FMOUT: 2.061 microseconds. GPS-MASER: 1.881 microseconds. Wx: Temperature (C): + 5, Pressure (mBar): 895, Humidity: 86. Sky Conditions: cloudy. Cable difference: -. SEFD X/S Source Az/El Offset1 Offset2 290/- 3c295 308/40 -0.01629 -0.00684 Tsys (x/s): 67/120. Mark5B+ recording. Azeloff (az/el): -1m30s/0m. Operator: Ptitcin A. ================================ crf114zc START ================================ 2019-11-28 14:00:12 crf114 Zelenchukskaya Start message Session crf114 start message for Zelenchukskaya. Experement started 14:00:00. First source: 2348-010 at 14:00:00 UT. Operator: Ptitcin A. ================================ crf114zc STOP ================================= 2019-11-29 14:01:19 crf114 Zelenchukskaya Stop message Session crf114 stop message for Zelenchukskaya. Zelenchukskaya ends crf114 at 14:00:00, observing 237. Scans from No332-1951 to No332-2054 missed due to participation in ri2930. Session crf114 were recorded on module IAAC+013. Operator: Lysenkova M. ================================================================================