Starting generation of Calibration File FS version = 0009.0011.0007 time_zero = 18550800 Found #3 errors of type = ERROR st -4 Interface not set to remote. Found #2 errors of type = ERROR st -6 Antenna control restored. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector ic. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 8u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 6u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 7u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 4u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector ia. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 1l. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 8u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 6u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 7u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 1u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 8l. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 4u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 3u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 2u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 5u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 8l. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector ic. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 3u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 5u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 1l. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 2u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 1u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector ia. Found these BBCs: bbc01 bbc05 bbc09 NBBC: 3 Found these SX parameters: slo xlo sup RX1 min= 3.87 max= 3.87 RX2 min= 4.70 max= 4.70 RX3 min= 251.59 max= 253.05 Can't plot RX1 Can't plot RX2 Plotting 3 Tsys channels: 01 05 09 Tsys values are: -1 1 2 etc NTSYS: 3 in match_chan ft1= i17214kk.log.tsy1.ntup nt1= 8 st1= 1u tt= 1 set scale tsys1 [2] min max 73.7 90.4 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 122.9 ymax 151.4 in match_chan ft1= i17214kk.log.tsy1.ntup nt1= 20 st1= 5u tt= 1 set scale tsys1 [2] min max 73.7 90.4 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 44.9 ymax 66.7 in match_chan ft1= i17214kk.log.tsy1.ntup nt1= 13 st1= 9u tt= 1 set scale tsys1 [2] min max 73.7 90.4 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 28.9 ymax 52.4