IVS Analysis Report for I19101 ($19APR11XU) This report is the official IVS analysis report that corresponds to the database maintained by the IVS Data Centers for this session. (Analyzed by Karen Baver, Goddard Space Flight Center VLBI Analysis Center. Spoolfile source: interactive solve/nuSolve analysis.) Problems: The KOKEE-SVETLOE and SVETLOE-WETTZELL baselines did not have enough good observations to be usable. Most observations that could have been included had very large residuals. The baselines were deselected. Number of observations rejected during correlation: 0 Number of observations not usable by the software: 5 observation 4, KOKEE :WETTZELL, 1418+546, 18:33:36, quality code X-band: 0 S-band: 9 observation 17, KOKEE :SVETLOE , NGC6251 , 18:57:19, quality code X-band: 9 S-band: 0 observation 18, KOKEE :WETTZELL, NGC6251 , 18:57:19, quality code X-band: 0 S-band: 0 observation 29, KOKEE :SVETLOE , 0415+398, 19:17:53, quality code X-band: 0 S-band: 9 observation 30, KOKEE :WETTZELL, 0415+398, 19:17:53, quality code X-band: 0 S-band: 9 Number of observations rejected during analysis: 18 The SVETLOE baselines were deselected due to having very few observations, which also had very high residuals. Other comments: None. Parameterization: 6 parameters: UT1 offset atmosphere offset for: KOKEE WETTZELL clock offset, first order term, and second order term for: WETTZELL Clock breaks: None Session Statistics Observations: 38 scheduled 38 correlated (included in the database) 33 recoverable (usable in Solve/nuSolve) 15 used Session fit: 66.237 ps UT1 formal error: 25.14 microsec Source Performance Number of Observations Scheduled Correlated* Used 0016+731 1 1 1 0059+581 4 4 2 0133+476 3 3 1 0322+222 1 1 1 0415+398 3 3 0 0718+793 3 3 1 1053+815 1 1 1 1418+546 1 1 0 NGC6251 3 3 0 1636+473 1 1 1 NRAO512 3 3 1 DA426 3 3 1 1803+784 3 3 1 1800+440 1 1 1 3C371 3 3 1 2229+695 4 4 2 ------------ --------- ---------- ------ Source Total 38 38 15 * Correlated means included in the database. Please note that the number of recoverable (usable) observations cannot be broken down by source for Intensive solutions.