IVS Analysis Report for I19206 ($19JUL25XU) This report is the official IVS analysis report that corresponds to the database maintained by the IVS Data Centers for this session. (Analyzed by Karen Baver, Goddard Space Flight Center VLBI Analysis Center. Spoolfile source: interactive solve/nuSolve analysis.) Problems: None. Number of observations rejected during correlation: 18 The session's final 18 (ISHIOKA:WETTZELL) observations were not included in the correlated data set: observation of 0642+449 at 19:09:55 observation of 1726+455 at 19:11:16 observation of 1751+288 at 19:12:12 observation of 1803+784 at 19:13:31 observation of 3C418 at 19:14:31 observation of 0016+731 at 19:15:27 observation of 0059+581 at 19:16:42 observation of 0642+449 at 19:17:38 observation of 1726+455 at 19:19:01 observation of 1803+784 at 19:20:08 observation of 3C418 at 19:21:07 observation of 0016+731 at 19:22:03 observation of 0059+581 at 19:23:18 observation of 0642+449 at 19:24:14 observation of 1726+455 at 19:25:38 observation of 1803+784 at 19:26:47 observation of 3C418 at 19:27:45 observation of 0016+731 at 19:28:41 Number of observations not usable by the software: 6 observation 5, ISHIOKA :WETTZELL, 0642+449, 18:34:44, quality code X-band: 0 S-band: 9 observation 14, ISHIOKA :WETTZELL, 0642+449, 18:46:03, quality code X-band: 0 S-band: 9 observation 18, ISHIOKA :WETTZELL, 1751+288, 18:50:13, quality code X-band: 9 S-band: 0 observation 23, ISHIOKA :WETTZELL, 0642+449, 18:55:38, quality code X-band: 0 S-band: 9 observation 29, ISHIOKA :WETTZELL, 0642+449, 19:02:23, quality code X-band: 0 S-band: 9 observation 31, ISHIOKA :WETTZELL, 1751+288, 19:04:40, quality code X-band: 8 S-band: 0 Number of observations rejected during analysis: 1 observation 30, ISHIOKA :WETTZELL, 1726+455, 19:03:43, which fits at 280.0 +/- 89.6 ps Other comments: Preliminary solution; the data for SVETLOE have not arrived yet. Parameterization: 6 parameters: UT1 offset atmosphere offset for: ISHIOKA WETTZELL clock offset, first order term, and second order term for: WETTZELL Clock breaks: None Session Statistics Observations: 89 scheduled (from all stations---includes SVETLOE) 53 scheduled (from available stations---does not include SVETLOE) 35 correlated (included in the database) 29 recoverable (usable in Solve/nuSolve) 28 used Session fit: 53.896 ps UT1 formal error: 30.62 microsec Source Performance Number of Observations Scheduled Correlated* Used 0016+731 16 5 5 0059+581 13 5 5 0642+449 7 4 0 NRAO512 4 2 2 1726+455 12 5 4 1751+288 10 5 3 1803+784 16 5 5 3C418 11 4 4 ------------ --------- ---------- ------ Source Total 89 35 28 * Correlated means included in the database. Please note that the number of recoverable (usable) observations cannot be broken down by source for Intensive solutions.