USNO Analysis Report for Q19231 ($19AUG19XK) This report is a contributed analysis report that does not correspond to the database maintained by the IVS Data Centers for this session. (Analyzed by Christopher Dieck, US Naval Observatory. Spoolfile source: interactive nuSolve analysis.) Problems: None. Number of observations rejected during correlation: 0 Number of observations not usable by the software: 2 observation 15, ISHIOKA :WETTZELL, 2000+472, 07:15:09, quality codes - S:0, X:9 observation 49, ISHIOKA :WETTZELL, 0642+449, 07:55:22, quality codes - S:9, X:0 Number of observations rejected during analysis: 2 observation 25, ISHIOKA :WETTZELL, 1726+455, 07:26:15, which fits at -394.6 +/- 53.4 ps observation 41, ISHIOKA :WETTZELL, 1133-032, 07:46:17, which fits at 194.9 +/- 46.6 ps Other comments: WETTZ13N was included in the schedule, but it did not participate because it is out for maintenance. Parameterization: 5 parameters: UT1 offset atmosphere offset for: ISHIOKA WETTZELL clock offset (0), first order term (1), and/or second order term (2) for: WETTZELL (0,1) Clock breaks: None Session Statistics Observations: 156 scheduled (from all stations---includes WETTZ13N) 52 scheduled (from available stations---does not include WETTZ13N) 52 correlated (included in the database) 50 recoverable (usable in Solve/nuSolve) 48 used Session fit: 36.130 ps UT1 formal error: 6.05 microsec Source Performance Number of Observations Scheduled Correlated* Used 0016+731 6 2 2 0059+581 6 2 2 0613+570 6 2 2 0642+449 6 2 1 0716+714 6 2 2 0805+410 6 2 2 0814+425 6 2 2 0827+243 6 2 2 OJ287 6 2 2 0955+476 6 2 2 1030+415 6 2 2 1039+811 6 2 2 1040+244 6 2 2 1053+704 6 2 2 1059+282 3 1 1 1128+385 3 1 1 1133-032 3 1 0 1144+402 6 2 2 1156+295 6 2 2 3C274 3 1 1 1417+385 6 2 2 1418+546 3 1 1 1726+455 3 1 0 1803+784 6 2 2 3C371 3 1 1 1849+670 6 2 2 2000+472 6 2 1 3C418 6 2 2 2229+695 6 2 2 2309+454 3 1 1 ------------ --------- ---------- ------ Source Total 156 52 48 * Correlated means included in the database. Please note that the number of recoverable (usable) observations cannot be broken down by source for Intensive solutions.