USNO Analysis Report for W19091 ($19APR01XW) This report is a contributed analysis report that does not correspond to the database maintained by the IVS Data Centers for this session. (Analyzed by Christopher Dieck, US Naval Observatory. Spoolfile source: interactive nuSolve analysis.) Problems: PIETOWN had trouble pointing, and no data was correlated. Number of observations rejected during correlation: 0 Number of observations not usable by the software: 2 observation 26, MK-VLBA :WETTZELL, NGC6251 , 08:58:27, quality codes - S:0, X:9 observation 27, MK-VLBA :WETTZELL, 1342+662, 09:01:06, quality codes - S:0, X:9 Number of observations rejected during analysis: 24 The WETTZ13N:WETTZELL baseline was deselected, accounting for 21 observations. observation 24, MK-VLBA :WETTZELL, 1639+230, 08:55:16, had a G-code on S-band observation 45, MK-VLBA :WETTZELL, 1342+662, 09:28:19, which fits at -2595.8 +/- 79.6 ps observation 73, MK-VLBA :WETTZELL, 0716+714, 10:02:32, had a G-code on S-band Other comments: None. Parameterization: 8 parameters: UT1 offset atmosphere offset for: MK-VLBA WETTZ13N WETTZELL clock offset (0), first order term (1), and/or second order term (2) for: WETTZ13N (0,1) WETTZELL (0,1) Clock breaks: None Session Statistics Observations: 225 scheduled 95 correlated (included in the database) 91 recoverable (usable in Solve/nuSolve) 69 used Session fit: 63.895 ps UT1 formal error: 6.77 microsec Source Performance Number of Observations Scheduled Correlated* Used 0602+673 3 1 1 0613+570 24 12 8 0641+392 3 1 1 0714+457 3 1 1 0716+714 24 12 7 0738+491 9 3 3 0800+618 3 1 1 0805+410 6 3 2 0955+476 24 12 8 1053+815 3 1 1 1300+580 9 3 3 1342+662 9 3 1 1418+546 18 9 6 1520+437 12 4 4 1606+106 6 3 2 NGC6251 3 1 0 1636+473 12 4 4 NRAO512 9 3 3 1639+230 12 4 3 1651+391 6 2 2 DA426 3 1 1 1746+470 3 1 1 1803+784 6 3 2 3C371 12 6 4 2229+695 3 1 0 ------------ --------- ---------- ------ Source Total 225 95 69 * Correlated means included in the database. Please note that the number of recoverable (usable) observations cannot be broken down by source for Intensive solutions.