USNO Analysis Report for W19178 ($19JUN27XW) This report is a contributed analysis report that does not correspond to the database maintained by the IVS Data Centers for this session. (Analyzed by Christopher Dieck, US Naval Observatory. Spoolfile source: interactive nuSolve analysis.) Problems: None. Number of observations rejected during correlation: 0 Number of observations not usable by the software: 3 observation 8, MK-VLBA :WETTZELL, 1929+226, 07:20:29, quality codes - S:9, X:0 observation 17, MK-VLBA :WETTZELL, 1636+473, 07:27:23, quality codes - S:0, X:9 observation 113, MK-VLBA :WETTZELL, 2141+175, 08:38:47, quality codes - S:9, X:0 Number of observations rejected during analysis: 5 observation 12, PIETOWN :WETTZELL, 1732+389, 07:23:35, which fits at -236.5 +/- 65.7 ps observation 52, MK-VLBA :PIETOWN , 1636+473, 07:55:12, has a G-code on S-band observation 72, PIETOWN :WETTZELL, 1418+546, 08:08:07, which fits at 11816.3 +/- 116.0 ps observation 111, PIETOWN :WETTZELL, 1418+546, 08:36:07, which fits at -11790.2 +/- 109.2 ps observation 121, MK-VLBA :PIETOWN , 1636+473, 08:44:36, has a G-code on S-band Other comments: None. Parameterization: 8 parameters: UT1 offset atmosphere offset for: MK-VLBA PIETOWN WETTZELL clock offset (0), first order term (1), and/or second order term (2) for: PIETOWN (0,1) WETTZELL (0,1) Clock breaks: None Session Statistics Observations: 162 scheduled 162 correlated (included in the database) 159 recoverable (usable in Solve/nuSolve) 154 used Session fit: 68.122 ps UT1 formal error: 7.21 microsec Source Performance Number of Observations Scheduled Correlated* Used 1053+815 3 3 3 1128+385 3 3 3 1144+402 3 3 3 1300+580 12 12 12 1342+662 9 9 9 1418+546 9 9 7 NGC6251 3 3 3 1636+473 15 15 12 1732+389 3 3 2 1746+470 3 3 3 1803+784 3 3 3 1800+440 3 3 3 3C371 15 15 15 1929+226 3 3 2 2013+163 3 3 3 2113+293 15 15 15 2141+175 9 9 8 2144+092 6 6 6 2209+236 9 9 9 2214+350 12 12 12 2215+150 9 9 9 2229+695 9 9 9 2319+317 3 3 3 ------------ --------- ---------- ------ Source Total 162 162 154 * Correlated means included in the database. Please note that the number of recoverable (usable) observations cannot be broken down by source for Intensive solutions.