IVS Analysis Report for I21273 ($21SEP30XU) This report is the official IVS analysis report that corresponds to the database maintained by the IVS Data Centers for this session. (Analyzed by Karen Baver, Goddard Space Flight Center VLBI Analysis Center. Spoolfile source: interactive solve/nuSolve analysis.) Problems: Six observations starting at 19:03:28 had good quality codes (9/9), but they fit at 10 ns and seemed to indicate sub-ambiguities in X-band. So these observations were removed from the solution, which only includes nine observations. Number of observations rejected during correlation: 0 Number of observations not usable by the software: 6 observation 7, KOKEE :WETTZELL, 1418+546, 18:45:31, quality code X: 0 S: 9, fringe code X: ' ' S: ' ' observation 11, KOKEE :WETTZELL, 0602+673, 18:53:30, quality code X: 8 S: 0, fringe code X: ' ' S: ' ' observation 12, KOKEE :WETTZELL, 0415+398, 18:57:38, quality code X: 9 S: 0, fringe code X: ' ' S: ' ' observation 13, KOKEE :WETTZELL, 0322+222, 19:00:32, quality code X: 9 S: 0, fringe code X: ' ' S: ' ' observation 16, KOKEE :WETTZELL, 1300+580, 19:10:47, quality code X: 0 S: 9, fringe code X: ' ' S: ' ' observation 17, KOKEE :WETTZELL, 0322+222, 19:14:28, quality code X: 9 S: 0, fringe code X: ' ' S: ' ' Number of observations rejected during analysis: 6 The following observations were deselected after indicating sub-ambiguities at X-band: observation 14, KOKEE :WETTZELL, 0307+380, 19:03:28, which fits at 9810.0 +/- 92.2 ps observation 15, KOKEE :WETTZELL, 0718+793, 19:07:10, which fits at 9914.6 +/- 107.1 ps observation 18, KOKEE :WETTZELL, 1308+328, 19:18:26, which fits at 9610.9 +/- 85.8 ps observation 19, KOKEE :WETTZELL, 0307+380, 19:23:18, which fits at 9485.4 +/- 91.1 ps observation 20, KOKEE :WETTZELL, 0529+483, 19:26:02, which fits at 9289.1 +/- 89.6 ps observation 21, KOKEE :WETTZELL, 0738+491, 19:28:08, which fits at 9280.0 +/- 85.2 ps Other comments: None. Parameterization: 6 parameters: UT1 offset atmosphere offset for: KOKEE WETTZELL clock offset, first order term, and second order term for: WETTZELL Clock breaks: None Session Statistics Observations: 21 scheduled 21 correlated (included in the database) 15 recoverable (usable in Solve/nuSolve) 9 used Session fit: 50.836 ps UT1 formal error: 35.61 microsec Source Performance Number of Observations Scheduled Correlated* Used 0016+731 1 1 1 0307+380 3 3 1 0322+222 2 2 0 0415+398 1 1 0 0529+483 2 2 1 0602+673 1 1 0 0716+714 1 1 1 0718+793 1 1 0 0738+491 2 2 1 0955+476 1 1 1 1144+402 1 1 1 1300+580 1 1 0 1308+328 1 1 0 1324+224 1 1 1 1418+546 1 1 0 1803+784 1 1 1 ------------ --------- ---------- ------ Source Total 21 21 9 * Correlated means included in the database. Please note that the number of recoverable (usable) observations cannot be broken down by source for Intensive solutions.