IVS Analysis Report for Q21102 ($21APR12XK) This report is the official IVS analysis report that corresponds to the database maintained by the IVS Data Centers for this session. (Analyzed by Karen Baver, Goddard Space Flight Center VLBI Analysis Center. Spoolfile source: interactive solve/nuSolve analysis.) Problems: None. Number of observations rejected during correlation: 0 Number of observations not usable by the software: 4 observation 46, SESHAN25:WETTZ13N, 0256-005, 07:22:53, quality code X: 0 S: 0, fringe code X: ' ' S: ' ' observation 47, SESHAN25:WETTZELL, 0256-005, 07:22:53, quality code X: 0 S: 0, fringe code X: ' ' S: ' ' observation 103, SESHAN25:WETTZ13N, 0256-005, 07:48:47, quality code X: 0 S: 0, fringe code X: ' ' S: ' ' observation 104, SESHAN25:WETTZELL, 0256-005, 07:48:47, quality code X: 0 S: 0, fringe code X: ' ' S: ' ' Number of observations rejected during analysis: 21 observation 3, WETTZ13N:WETTZELL, 2355-106, 07:00:15, which fits at 2599.7 +/- 41.2 ps observation 5, SESHAN25:WETTZELL, 2325+093, 07:01:36, which fits at -116.5 +/- 34.7 ps observation 6, WETTZ13N:WETTZELL, 2325+093, 07:01:36, which fits at -977.7 +/- 40.9 ps observation 11, SESHAN25:WETTZELL, 3C418 , 07:04:30, which fits at 128.6 +/- 29.8 ps observation 18, WETTZ13N:WETTZELL, 1053+704, 07:07:25, which fits at 2367.8 +/- 43.6 ps observation 19, SESHAN25:WETTZ13N, 0955+476, 07:08:52, which fits at -332.5 +/- 60.6 ps observation 21, WETTZ13N:WETTZELL, 0955+476, 07:08:52, which fits at 412.1 +/- 42.7 ps observation 24, WETTZ13N:WETTZELL, 0738+491, 07:10:35, which fits at -1870.7 +/- 42.3 ps observation 45, WETTZ13N:WETTZELL, 0322+222, 07:21:13, which fits at 497.6 +/- 41.8 ps observation 48, WETTZ13N:WETTZELL, 0256-005, 07:22:53, which fits at -13289.7 +/- 60.8 ps observation 51, WETTZ13N:WETTZELL, 0215+015, 07:24:07, which fits at 3565.5 +/- 41.6 ps observation 57, WETTZ13N:WETTZELL, 2309+454, 07:27:27, which fits at -20578.5 +/- 44.0 ps observation 69, WETTZ13N:WETTZELL, 1053+704, 07:32:43, which fits at 18238.4 +/- 44.1 ps observation 72, WETTZ13N:WETTZELL, 0716+714, 07:34:13, which fits at -3261.0 +/- 41.3 ps observation 75, WETTZ13N:WETTZELL, 0718+793, 07:35:22, which fits at 3401.6 +/- 42.0 ps observation 78, WETTZ13N:WETTZELL, 2353+816, 07:36:41, which fits at -23899.0 +/- 43.4 ps observation 93, WETTZ13N:WETTZELL, 0307+380, 07:43:14, which fits at 2591.3 +/- 43.0 ps observation 105, WETTZ13N:WETTZELL, 0256-005, 07:48:47, which fits at 13643.3 +/- 57.1 ps observation 114, WETTZ13N:WETTZELL, 0019+058, 07:53:31, which fits at 293.2 +/- 42.9 ps observation 120, WETTZ13N:WETTZELL, 2319+317, 07:55:59, which fits at -18262.7 +/- 44.1 ps observation 123, WETTZ13N:WETTZELL, 2309+454, 07:57:13, which fits at -21011.1 +/- 44.6 ps Other comments: The correlator report provided the following station notes: SESHAN25 (Sh/C): Ok. WETTZ13N (Wn/W): RFI in S-band channel SR1U and SR3U on baseline Wn-Wz; channels removed from fringe fitting on this baseline. WETTZELL (Wz/V): RFI in S-band channel SR1U and SR3U on baseline Wn-Wz; channels removed from fringe fitting on this baseline. Parameterization: 10 parameters: UT1 offset atmosphere offset for: SESHAN25 WETTZ13N WETTZELL clock offset, first order term, and second order term for: WETTZ13N WETTZELL Clock breaks: None Session Statistics Observations: 126 scheduled 126 correlated (included in the database) 122 recoverable (usable in Solve/nuSolve) 101 used Session fit: 40.703 ps UT1 formal error: 6.48 microsec Source Performance Number of Observations Scheduled Correlated* Used 0016+731 3 3 3 0017+200 3 3 3 0019+058 3 3 2 0059+581 6 6 6 0133+476 3 3 3 0201+113 6 6 6 0202+319 6 6 6 0215+015 3 3 2 0221+067 6 6 6 0229+131 6 6 6 0235+164 6 6 6 0256-005 6 6 0 0307+380 3 3 2 0322+222 6 6 5 0529+483 3 3 3 0716+714 3 3 2 0718+793 3 3 2 0738+491 3 3 2 0955+476 3 3 1 1039+811 3 3 3 1053+704 6 6 4 1803+784 3 3 3 3C371 3 3 3 3C418 3 3 2 2214+241 3 3 3 2229+695 6 6 6 2309+454 6 6 4 2319+317 3 3 2 2325+093 3 3 1 2353+816 3 3 2 2355-106 3 3 2 ------------ --------- ---------- ------ Source Total 126 126 101 * Correlated means included in the database. Please note that the number of recoverable (usable) observations cannot be broken down by source for Intensive solutions.