IVS Analysis Report for V21245 ($21SEP02VI) This report is the official IVS analysis report that corresponds to the database maintained by the IVS Data Centers for this session. (Analyzed by Sergei Bolotin, NVI, Inc. / NASA Goddard Space Flight Center. Spoolfile source: interactive solve/nuSolve analysis.) Problems: KOKEE12M Phase reference station. Number of observations rejected during correlation: 0 Number of observations not usable by the software: 0 Number of observations rejected during analysis: 1 observation 13, KOKEE12M:WETTZ13S, 3C274 , 18:47:04, which fits at 371.2 +/- 68.1 ps Other comments: None. Parameterization: 6 parameters: UT1 offset atmosphere offset for: KOKEE12M WETTZ13S clock offset, first order term, and second order term for: WETTZ13S Clock breaks: None Session statistics Observations: 45 scheduled 45 correlated (included in the database) 45 recoverable (usable in Solve/nuSolve) 44 used Session fit: 61.958 ps UT1 formal error: 9.03 microsec Source Performance Number of Observations Scheduled Correlated* Used 0016+731 1 1 1 0109+224 1 1 1 0202+319 2 2 2 0307+380 2 2 2 0529+483 3 3 3 0602+673 2 2 2 0613+570 1 1 1 0716+714 1 1 1 0718+793 2 2 2 0738+491 3 3 3 0955+476 2 2 2 1015+359 1 1 1 1030+415 2 2 2 1039+811 1 1 1 1053+704 1 1 1 1059+282 1 1 1 1128+385 1 1 1 1144+402 3 3 3 1212+171 1 1 1 3C274 2 2 1 1300+580 1 1 1 1306+360 3 3 3 1308+328 3 3 3 1324+224 1 1 1 1418+546 2 2 2 1803+784 2 2 2 ------------ --------- ---------- ------ Source Total 45 45 44 * Correlated means included in database. Please note that the number of recoverable (usable) observations cannot be broken down by source for Intensive solutions.